Customer had a Legacy Variable Frequency Drive that failed. Repair was not possible and drive was discontinued making replacement impossible. KTG was able to replace the VFD drives with new ones available form Automation Direct. Since the new drives were modern and programmable we were able to reprogram the drives to accept the legacy machine inputs and outputs. By doing so we were able to integrate the new drives into the legacy machine without changes to the original motors or control circuity.